Travel and access
The ADS-800 has a listed effective stroke of 500 × 300 × 100 mm. Check the fixture, part edges, nozzle approach and loading access within that envelope.
CCD positioning
Vision positioning establishes the relationship between the part and the dispensing path. The chosen reference features must remain visible under the planned lighting and fixture arrangement.
Motion and dispensing
Listed maximum motion speeds are 1000 mm/s on XY and 600 mm/s on Z. Actual application speed also follows adhesive flow, bead geometry, acceleration and corner behaviour. Record deposit and path results during the process trial.