Motion precision
The ADS-800 lists ±0.01 mm mechanical precision. Use this figure when reviewing the positioning task, fixture and programmed path; it does not describe material weight or cured bond strength.
Material delivery
The supplied proportioning and dispensing precision is ≤±3%. A/B ratio and total deposit quantity should be evaluated separately from nozzle position.
A complete trial
Run representative parts through loading, CCD alignment, dispensing and inspection. Record adhesive condition, the selected valve and feed package, deposit results and changeover settings so the trial can be repeated.